EN_BOM_MMC_ADOP

(SQL Table)
Index Back

BOM Mass Maint Add Ouptputs

04/21/99 LAJ CN#EN800-6.0 This record is a child table to EN_BOM_MMC and stores output information that is to be added during BOM Mass Maintenance. 10/02/02 PWF PL880-1.0 Remove reference to EP_OP_SEQ

# PeopleSoft Field Name PeopleSoft Field Type Database Column Type Description
1 MASS_MAINT_CODE Character(10) VARCHAR2(10) NOT NULL Mass Maintenance Code
2 MASS_MAINT_SEQ Number(3,0) SMALLINT NOT NULL Mass Maintenance Sequence
3 BUSINESS_UNIT Character(5) VARCHAR2(5) NOT NULL Business Unit
4 INV_ITEM_ID Character(18) VARCHAR2(18) NOT NULL Item ID
5 BOM_STATE Character(2) VARCHAR2(2) NOT NULL BOM State
EN=Engineering
PR=Manufacturing
6 BOM_TYPE Character(2) VARCHAR2(2) NOT NULL 03/26/00 RML Added a label "Type"
PR=Production
RW=Rework
7 BOM_CODE Number(2,0) SMALLINT NOT NULL CN# EN800-3.0, anna 09/21 added new field to database
8 MG_OUTPUT_TYPE Character(2) VARCHAR2(2) NOT NULL 10/22/98 (CN#EN800-6.0) LAJ...Created Stores the output item type on a Bill of Materials. The type could represent either a co-product (primary or secondary) or a by-product (waste or recycle). 11/23/98 (CN#SF800-13) JNW added teardown xlat
CP=Primary
CS=Co-Product
RB=Recycle
TD=Teardown
WB=Waste
9 MG_OUTPUT_ITEM Character(18) VARCHAR2(18) NOT NULL 04/10/00 (Internet Architecture) SCC: Uppercase label Id. 10/22/98 (CN#EN800-6.0) LAJ...Created Stores the output item number on a Bill of Materials. This item may be either a co-product or a by-product on the BOM. The output type field determines which one it represents. There should always be at least one output item on the BOM at all times; this output item is the same as the BOMs item id.

Prompt Table: %EDITTABLE5

10 OP_SEQUENCE Number(4,0) SMALLINT NOT NULL Operation Sequence

Prompt Table: %EDITTABLE2

11 DATE_IN_EFFECT Date(10) DATE NOT NULL 01/27/2000 RML Added "As of date" label 03/23/2004 SFC Added PRICE_LIST_DATE label 06/04/2004 SFC Added PRODUCT_PRICE_DAT label
12 DATE_OBSOLETE Date(10) DATE NOT NULL Obsolete Date
13 MG_OUTPUT_QTY Number(12,4) DECIMAL(11,4) NOT NULL 10/22/98 (CN#EN800-6.0) LAJ...Created Stores the output item quantity on a Bill of Materials. This value is assumed to be in the UOM of the output item it's associated to. KPN 08/23/02: Added label Quantity
14 MG_OUTPUT_QTY_CODE Character(3) VARCHAR2(3) NOT NULL 01/28/98 (CN#EN800-6.0) LAJ...Created Stores the quantity code for an output item on a Bill of Materials. It was created with the same values as qty_code, but by separating these two fields, it allows greater flexibility in the future.
ASY=Assembly
ORD=Order

Default Value: ASY

15 MG_OUTPUT_RES_PCT Number(3,0) SMALLINT NOT NULL 10/22/98 (CN#EN800-6.0) LAJ...Created Stores the output item's resource allocation percentage on a Bill of Material. Since it is a percentage, it cannot store a value greater than 100. It is used to determine what percentage of the inputs (components) on the BOM are used to produce the output (co-product).
16 MG_OUTPUT_COST_PCT Number(3,0) SMALLINT NOT NULL 10/22/98 (CN#EN800-6.0) LAJ...Created Stores the output item's cost percentage on a Bill of Material. Since it is a percentage, it cannot store a value greater than 100. It is used to determine what percentage of the cost to make the BOM goes to each output (co-product).
17 INCR_REL_TYPE Character(1) VARCHAR2(1) NOT NULL 07/22/02 EGS (CN#PL880-1): Added
1=None
2=Over Time

Default Value: 1

18 INCR_REL_OFFSET Number(16,4) DECIMAL(15,4) NOT NULL 07/22/02 EGS (CN#PL880-1): Added.
19 EN_BOM_MMC_EDATE Character(3) VARCHAR2(3) NOT NULL 02/03/99 laj CN#EN800-5.0 Flag used in BOM Mass Maintenance when the user wishes to use the auto increment revision functionality. This flag will determine what the effective date should be set to a component/output change.
SCH=Schd Date
20 EN_BOM_MMC_ODATE Character(3) VARCHAR2(3) NOT NULL 02/03/99 laj CN#EN800-5.0 Flag used in BOM Mass Maintenance when the user wishes to use the auto increment revision functionality. This flag will determine what the obsolete date should be set to a component/output change.
PRI=Prior Date
SCH=Schd Date